Performance of a large area photon detector for rare event search applications
Abstract
We present the design and characterization of a large-area Cryogenic PhotoDetector designed for active particle identification in rare event searches, such as neutrinoless double beta decay and dark matter experiments. The detector consists of a 45.6 cm 2 surface area by a 1-mm-thick 10.6 g Si wafer. It is instrumented with a distributed network of Quasiparticle-trap-assisted Electrothermal feedback Transition-edge sensors with superconducting critical temperature T c = 41.5 mK to measure athermal phonons released from interactions with photons. The detector is characterized and calibrated with a collimated 55Fe x-ray source incident on the center of the detector. The noise equivalent power is measured to be 1 × 10 - 17 W / √{ Hz } in a bandwidth of 2.7 kHz . The baseline energy resolution is measured to be σ E = 3.86 ± 0.04 (stat . ) - 0.00 + 0.19 ( syst . ) eV . The detector also has an expected timing resolution of σ t = 2.3 μ s for 5 σ E events.
- Publication:
-
Applied Physics Letters
- Pub Date:
- January 2021
- DOI:
- Bibcode:
- 2021ApPhL.118b2601F