FTIR Laboratory Measurement of O I Spectra in the 0.77-12.5 μm Spectral Range: Rydberg States and Oscillator Strengths
Abstract
Precision laboratory measurements are presented for 135 O I lines in the infrared (including 51 lines not measured previously in the laboratory) using time-resolved Fourier transform infrared spectroscopy in the 800-13,000 cm-1 region. The fine structure of some lines is observed for the first time. Using our linelist together with all relevant measurements from other works, we perform a re-optimization of O I level energies to obtain an internally consistent system of 2p 3[4 S]nl levels. Some O I level energies measured long ago are corrected. We also present a long list of oscillator strengths calculated with the help of quantum defect theory.
- Publication:
-
The Astrophysical Journal Supplement Series
- Pub Date:
- November 2018
- DOI:
- 10.3847/1538-4365/aae5f8
- Bibcode:
- 2018ApJS..239...11C
- Keywords:
-
- atomic data;
- methods: laboratory: atomic;
- techniques: spectroscopic