A new combined nanoSIMS and continuous-flow IRMS approach to measure hydrogen isotopes from water in hydrated rhyolitic glass
Abstract
The hydrogen-isotope value of water of hydration (or secondary water) preserved in rhyolitic glasses may provide significant insights regarding the climate at the time of their deposition and the impact of super-eruptions upon the environment. However, the ability of the glass to retain the environmental D/H isotopic signal after hydration needs to be tested, since modifications to the D/H systematics may result from the continuous exchange of D/H with the atmosphere or condensed water after initial glass hydration. Ideal geological archives to test whether the glass retains its original hydrogen signal are sediments in natural waters and ice cores, which preserve tephra in constrained horizons that can be independently isotopically characterised. However, tephra in marine and fresh water sediments and ice cores are often present in concentrations of the order of 1000 grains/cm3 (<5 mg of collectible material). Traditional IRMS methods require much more material ( 100-500 mg) and therefore cannot be applied. We present here a new integrated nanoSIMS and continuous flow IRMS approach to understand how water is distributed within single glass grains (diffusion profiles), quantify the time of hydration of young (Holocene) and old (Miocene) already well-characterised rhyolitic glasses, and measure the D/H ratio of the hydration water on single grains and bulk material consisting of only approximately 0.1-1 mg. The IRMS method measures the absolute abundance of hydrogen released from the sample by continuous-flow mass spectrometry. Current data indicates that the method can accurately measure a hydrogen signal from a rock sample containing at least 400 nanomoles of H2, corresponding to 70 µg of water, which translates to 1 mg of hydrous glass (>3 wt%) or 15 mg of dry ( 0.5 wt%) obsidian chips. The method can be improved by reducing the blank to <1 nmol/min and reducing capillary empty space. The bulk results obtained with the continuous-flow IRMS method will be compared to sub-micron mapping of single-grains using a high-resolution ion microprobe, the CAMECA NanoSIMS 50L, in the Microanalysis Center for Geochemistry and Cosmochemistry at California Institute of Technology, in order to define the reliability of the bulk method and assess natural variability within and among grains.
- Publication:
-
AGU Fall Meeting Abstracts
- Pub Date:
- December 2016
- Bibcode:
- 2016AGUFM.V43B3155G
- Keywords:
-
- 1040 Radiogenic isotope geochemistry;
- GEOCHEMISTRYDE: 1041 Stable isotope geochemistry;
- GEOCHEMISTRYDE: 1094 Instruments and techniques;
- GEOCHEMISTRYDE: 5494 Instruments and techniques;
- PLANETARY SCIENCES: SOLID SURFACE PLANETS