R&D activities on RF contacts for the ITER ion cyclotron resonance heating launcher
Abstract
CEA have developed a dedicated test-bed for testing RF contact in ITER relevant conditions (vacuum, temperature, RF current). A prototype of RF contacts have been designed and manufactured, with copper lamellas brazed on a titanium holder. This RF contact prototype failed at RF current larger than 1.8kA. Extensive R&D is foreseen with new RF contact designs.