High-contrast imager for complex aperture telescopes (HiCAT): 3. first lab results with wavefront control
Abstract
HiCAT is a high-contrast imaging testbed designed to provide complete solutions in wavefront sensing, control and starlight suppression with complex aperture telescopes. The pupil geometry of such observatories includes primary mirror segmentation, central obstruction, and spider vanes, which make the direct imaging of habitable worlds very challenging. The testbed alignment was completed in the summer of 2014, exceeding specifications with a total wavefront error of 12nm rms over a 18mm pupil. The installation of two deformable mirrors for wavefront control is to be completed in the winter of 2015. In this communication, we report on the first testbed results using a classical Lyot coronagraph. We also present the coronagraph design for HiCAT geometry, based on our recent development of Apodized Pupil Lyot Coronagraph (APLC) with shaped-pupil type optimizations. These new APLC-type solutions using two-dimensional shaped-pupil apodizer render the system quasi-insensitive to jitter and low-order aberrations, while improving the performance in terms of inner working angle, bandpass and contrast over a classical APLC.
- Publication:
-
Techniques and Instrumentation for Detection of Exoplanets VII
- Pub Date:
- September 2015
- DOI:
- 10.1117/12.2188497
- arXiv:
- arXiv:1911.03734
- Bibcode:
- 2015SPIE.9605E..0IN
- Keywords:
-
- Astrophysics - Instrumentation and Methods for Astrophysics;
- Astrophysics - Earth and Planetary Astrophysics
- E-Print:
- 12 pages, 10 figures, Proceedings of the SPIE, Volume 9605, id. 96050I 12 pp. (2015)