A new determination of the 209Po half-life
Abstract
A substantial 25% error in the then-known and accepted (102 ± 5) year half-life of 209Po was reported on in 2007. This error was detected from decay data from two separate primary standardizations of a 209Po solution standard, which were performed approximately 12 years apart. Despite author claims that this observation was not a new half-life determination, it was nevertheless included in subsequent nuclear data evaluations and compilations to obtain a currently tabulated value of (115 ± 13) a, computed from the median and range of the two half-life reports. A third primary standardization on the identical 209Po solution has since been performed to derive a new half-life value of (125.2 ± 3.3) a. This half-life determination was obtained from 30 distinct data sets over a period of 20.7 years, encompassing over 700 liquid scintillation measurements with nearly 50 counting sources all prepared from the same solution, and as obtained over a very broad range of measurement conditions (composition of cocktails, characteristics of counters, time sequencing) during five periods in 1993, 1994, 2005, and 2013.
- Publication:
-
Journal of Physics G Nuclear Physics
- Pub Date:
- October 2014
- DOI:
- Bibcode: