The Iceland Deep Drilling Project (IDDP): Deep Fluid Sampling in Fractured Quartz, Reykjanes Geothermal System, Iceland
Abstract
In July of 2011 a fluid inclusion tool (FIT) was deployed in well RN-17b of the Reykjanes geothermal system, Iceland, with the goal of sampling fluids in situ at the deepest feed point in the well. The tool consists of a perforated stainless steel pipe containing eight stainless steel mesh canisters, each loaded with 10mm-scale blocks of thermally fractured quartz. Except for one control canister, in each canister the fractured quartz blocks were surrounded by a different grain size of SiO¬2 glass that ranged in size from 10μm-scale glass wool to cm-scale glass shards. The FIT was left in the well on a wireline at a depth of 2768m and retrieved after three weeks. The fluid at 2768m depth is known from November 2010 well logs to have a temperature of about 330°C and pressure of 170 bars, a pressure ~40 bar too high for boiling at that temperature. After retrieval, quartz in all of the canisters contained liquid-dominated fluid inclusions, but their quantity and size differed by canister. Groups of inclusions occur in healed fractures and both healed and open fracture surfaces are visible within single quartz blocks. Measurements on a heating and cooling stage yield approximant inclusion homogenization temperatures of 332°C and freezing points of -2.0°C. These measurements and a pressure of 170 bars yield trapping temperatures of 335°C and a NaCl weight percent of 3.4, both of which match known values, thus verifying that the device trapped fluids as intended. In upcoming studies, these fluids will be analyzed using bulk methods and LA-ICP-MS on individual inclusions. The glass added to the quartz blocks in the canisters allowed the Reykjanes fluids to precipitate enough quartz to heal fractures and trap fluids despite the fluid undersaturation in quartz. Almost all of the glass that was added to the canisters, 27 to 66 grams in each (except glass wool), was consumed in the experiment. Remaining glass was in the non-mesh bottom caps of the canisters where fluid flux may have been minimal, indicating that most of the dissolved SiO2 was carried away with flowing fluid. This may explain why not all fractures were healed, as they were in our previous closed-system laboratory experiments. Upon recovery from the well, the FIT and the canister contents were covered in fine black particles, the greatest quantity by far occurring in canisters that had contained glass wool as the SiO2 source. Preliminary SEM-EDS analyses show that the particles contain silica, iron, magnesium, and small amounts of zinc sulfide. The precipitation of sulfides from the fluid sampled in the quartz fractures provides a valuable constraint on interpretation of the fluid inclusion compositions.
- Publication:
-
AGU Fall Meeting Abstracts
- Pub Date:
- December 2011
- Bibcode:
- 2011AGUFM.H21E1167S
- Keywords:
-
- 1034 GEOCHEMISTRY / Hydrothermal systems;
- 1043 GEOCHEMISTRY / Fluid and melt inclusion geochemistry;
- 1094 GEOCHEMISTRY / Instruments and techniques;
- 8424 VOLCANOLOGY / Hydrothermal systems