Polyvinylidene fluoride dust detector response to particle impacts
Abstract
Polyvinylidene fluoride (PVDF) dust detectors have flown on many space missions since their first use on the Vega 1 and 2 spacecraft. The fundamental operating principle of these detectors is the production of a charge upon impact by a hypervelocity dust particle. This measured signal, N, depends on the speed, v, and mass, m, of the particle. The relationship between N, v, and m was first empirically derived by Simpson and Tuzzolino. All of the PVDF dust instruments prior to the Student Dust Counter on the New Horizons mission use their formula for the calibration of the detectors. This paper provides additional dust impact calibration data, proposes a modification in the exponents for m and v, and investigates the relationship between detector temperature and detector signal.
- Publication:
-
Review of Scientific Instruments
- Pub Date:
- March 2010
- DOI:
- 10.1063/1.3340880
- Bibcode:
- 2010RScI...81c4501J
- Keywords:
-
- cosmic dust;
- sensors;
- 95.30.Wi;
- 07.07.Df;
- Dust processes;
- Sensors;
- remote sensing