A photon calorimeter using lead tungstate crystals for the CEBAF Hall A Compton polarimeter
Abstract
A new Compton polarimeter is built on the CEBAF Hall A electron beam line. Performances of 10% resolution and 1% calibration are required for the photon calorimeter of this polarimeter. This calorimeter is built with lead tungstate scintillators coming from the CMS electromagnetic calorimeter R&D. Beam tests of this detector have been made using the tagged photon beam line at MAMI, Mainz, and a resolution of 1.76%⊕2.75%/ E⊕0.41%/E has been measured.
- Publication:
-
Nuclear Instruments and Methods in Physics Research A
- Pub Date:
- April 2000
- DOI:
- 10.1016/S0168-9002(99)01092-X
- arXiv:
- arXiv:hep-ex/9907047
- Bibcode:
- 2000NIMPA.443..231N
- Keywords:
-
- High Energy Physics - Experiment
- E-Print:
- 13 pages