Gas Proportional Detectors with Interpolating Cathode Pad Readout for High Track Multiplicities
Abstract
New techniques for position encoding in very high rate particle and photon detectors will be required in experiments planned for future particle accelerators such as the Superconducting Super Collider and new, high intensity, synchrotron sources. Studies of two interpolating cathode 'pad' readout systems are described in this thesis. They are well suited for high multiplicity, two dimensional unambiguous position sensitive detection of minimum ionizing particles and heavy ions as well as detection of x-rays at high counting rates. One of the readout systems uses subdivided rows of pads interconnected by resistive strips as the cathode of a multiwire proportional chamber (MWPC). A position resolution of less than 100 μm rms, for 5.4keV x-rays, and differential non-linearity of 12% have been achieved. Low mass ( ~0.6% of a radiation length) detector construction techniques have been developed. The second readout system uses rows of chevron shaped cathode pads to perform geometrical charge division. Position resolution (FWHM) of about 1% of the readout spacing and differential non-linearity of 10% for 5.4keV x-rays have been achieved. A review of other interpolating methods is included. Low mass cathode construction techniques are described. In conclusion, applications and future developments are discussed.
- Publication:
-
Ph.D. Thesis
- Pub Date:
- February 1991
- Bibcode:
- 1991PhDT........61Y
- Keywords:
-
- PAD CHAMBER;
- Physics: Elementary Particles and High Energy; Physics: Nuclear; Physics: Radiation