Carbon monoxide analysis of future attainment of the NAAQS (National Ambient Air Quality Standard) in Wichita, Kansas
Abstract
In order to comply with the NAAQS for CO in Wichita, Kansas, a special study was performed to demonstrate that CO concentrations at a special purpose monitor (SPM) located near Douglas and Main Streets would give results less than the NAAQS by 1987. The SPM site is located near the urban core in an area characterized by high nighttime traffic volumes and congested traffic flow. A dispersion modeling analysis was performed using the CALINE-3 Model for dispersion, the MOBILE-3 Model for vehicle emissions and local or national traffic and ambient conditions. Results of modeling the SPM site for baseline (1983) emissions were calibrated with maximum measured CO concentrations. Several scenarios were analyzed in this analysis including with and without the inspection/maintenance program and with and without the left-turn ban from Douglas to Main Streets.
- Publication:
-
Final Report PEI Associates
- Pub Date:
- June 1985
- Bibcode:
- 1985peia.rept.....S
- Keywords:
-
- Air Pollution;
- Air Quality;
- Carbon Monoxide;
- Highways;
- Standards;
- Exhaust Emission;
- Mathematical Models;
- Monitors;
- Traffic;
- Engineering (General)