Hot-spot investigations of utility scale panel configurations
Abstract
The causes of array faults and efforts to mitigate their effects are examined. Research is concentrated on the panel for the 900 kw second phase of the Sacramento Municipal Utility District (SMUD) project. The panel is designed for hot spot tolerance without comprising efficiency under normal operating conditions. Series/paralleling internal to each module improves tolerance in the power quadrant to cell short or open circuits. Analtyical methods are developed for predicting worst case shade patterns and calculating the resultant cell temperature. Experiments conducted on a prototype panel support the analytical calculations.
- Publication:
-
Flat-Plate Solar Array Proj. Res. Forum on the High-Speed Growth and Characterization of Crystals for Solar Cells
- Pub Date:
- April 1984
- Bibcode:
- 1984fpsa.proc...37A
- Keywords:
-
- Design Analysis;
- Electrical Faults;
- Failure Analysis;
- Solar Arrays;
- Temperature Effects;
- Circuit Protection;
- Heat Transfer;
- Heating;
- Shadows;
- Temperature Measurement;
- Electronics and Electrical Engineering