Embedded gage impact study
Abstract
Impact damage in graphite/epoxy laminates was characterized and transient strain history during impact was correlated. The material investigated was AS-4/3501-6 graphite/epoxy. Eight-ply and sixteen-ply quasi-isotropic laminates of 45/0/-45/90 sub s and 45/0/-45/90 sub 2s layups were fabricated with strain gages embedded between plies during the strain gages and leads from the highly conductive graphite fibers. The specimens were circular plates 12.7 cm (5 in.) in diameter and clamped along their circumference. The specimens were impacted with a 185 gm impactor, dropped from heights of 1.20 m and 1.65 m. An accelerometer was attached to the back surface of the specimen opposite the impact point and was used to trigger the recording instrumentation. The transient strain data were recorded with an eight channel waveform digitizer capable of sampling data at 0.5 microsec intervals. The data were stored, processed, and plotted by means of a microcomputer. Transient strain data were correlated with results from ultrasonic inspection of the specimens.
- Publication:
-
NASA STI/Recon Technical Report N
- Pub Date:
- January 1984
- Bibcode:
- 1984STIN...8417558S
- Keywords:
-
- Deformation;
- Graphite-Epoxy Composites;
- Impact Damage;
- Laminates;
- Embedding;
- Strain Gages;
- Ultrasonic Tests;
- Instrumentation and Photography