Cathode charge distributions in multiwire chambers. I. Measurement and theory
Abstract
Detailed measurements under carefully defined conditions have been made of cathode charge distributions in a multiwire chamber. Wire and continuous cathodes have been employed. These measurements are in close agreement with theoretical predictions which take into account avalanche angular position and spread, and induced charge time development and signal processing.
- Publication:
-
Nuclear Instruments and Methods in Physics Research A
- Pub Date:
- November 1984
- DOI:
- 10.1016/0168-9002(84)90132-3
- Bibcode:
- 1984NIMPA.227..267G