Sparger system for MMH-helium vents
Abstract
Based on a calculated vent flow rate and MMH concentration, a TI-59 program was run to determine total sparger hole area for a given sparger inlet pressure. Hole diameter is determined from a mass transfer analysis in the holding tank to achieve complete capture of MMH. In addition, based on oxidation kinetics and vapor pressure data, MMh atmospheric concentrations are determined 2 ft above the holding tank.
- Publication:
-
In its The 1983 NASA/ASEE Summer Faculty Fellowship Research Program Research Reports 17 p (SEE N86-14078 04-85
- Pub Date:
- September 1983
- Bibcode:
- 1983asee.nasaR....R
- Keywords:
-
- Design Analysis;
- Flow Velocity;
- Helium;
- Inlet Flow;
- Inlet Pressure;
- Methylhydrazine;
- Venting;
- Computer Programs;
- Computerized Simulation;
- Data Reduction;
- Mathematical Models;
- Fluid Mechanics and Heat Transfer