Fundamental and harmonic operation of millimeter-wave Gunn diodes
Abstract
Pulsed and CW measurements in the range 26-110 GHz were performed on gallium arsenide Gunn diodes having active lengths of 1.8-2.6 microns bonded into commercially available packages. The diodes were operated in full-height waveguides in the V-(WR-15), E-(WR-12), and W-(WR-10) bands, using coaxial-bias circuits and a disc-post resonator to provide the required resonance at their fundamental frequency in the range from about 25-65 GHz. Frequency and power measurements were performed up to 110 GHz on the fundamental, second, and third harmonics. The main emphasis of this experimental investigation has been the study of frequency changes caused by changes made in the various parameters of the disc, post, diode, diode package, and embedding waveguide sections.
- Publication:
-
IEEE Transactions on Microwave Theory Techniques
- Pub Date:
- November 1983
- DOI:
- 10.1109/TMTT.1983.1131627
- Bibcode:
- 1983ITMTT..31..879H
- Keywords:
-
- Gallium Arsenides;
- Gunn Diodes;
- Harmonic Generations;
- Microwave Oscillators;
- Millimeter Waves;
- Cavity Resonators;
- Computerized Simulation;
- Continuous Radiation;
- Equivalent Circuits;
- Frequency Measurement;
- Harmonic Oscillators;
- Power Conditioning;
- Pulsed Radiation;
- Electronics and Electrical Engineering