Critical heat flux in a closed two-phase thermosyphon
Abstract
An experimental study was made of critical heat flux in a closed two-phase thermosyphon. The effects of inside diameter, heated length, working liquid, fill charge and inside temperature on the critical heat flux were investigated. The present and previously-published experimental data were correlated with expressions already proposed by other investigators but the agreements were not good. Accordingly, a new correlating expression was derived. This expression agrees with the experimental data within + or - 30 percent accuracy. Also, discussion of the adequate fill charge is made.