The non-Z2 response of the heavy nuclei cosmic ray detector on HEAO-3.
Abstract
A combination of ion chambers and Cerenkov radiators similar to the Heavy Nuclei Experiment flown on HEAO-3 was calibrated at the Bevalac heavy-ion accelerator using beams of Mn-25 nuclei at kinetic energies up to about 1700 MeV/nucleon and Au-79 nuclei up to about 1000 MeV/nucleon. The data show only a small deviation (about 2-3 charge units at Au) from the Z-squared scaling used previously (Binns et al., 1981, 1982, 1983) to analyze the HNE data. Although at lower energy, the calibration indicates that the published relative abundances of the Sn-50/Ba-56 group and the published upper-limit actinide abundances are not likely to be significantly affected by non-Z-squared effects.