USAF bioenvironmental noise data handbook. Volume 163: GPC-28 compressor
Abstract
The GPC-28 is a gasoline engine-driven compressor with a 120 volt 60 Hz generator used for general purpose maintenance. This report provides measured and extrapolated data defining the bioacoustic environments produced by this unit operating outdoors on a concrete apron at a normal rated condition. Near-field data are reported for 37 locations in a wide variety of physical and psychoacoustic measures: overall and band sound pressure levels, C-weighted and A-weighted sound levels, preferred speech interference level, perceived noise level, and limiting times for total daily exposure of personnel with and without standard Air Force ear protectors. Far-field data measured at 36 locations are normalized to standard meteorological conditions and extrapolated from 10 - 1600 meters to derive sets of equal-value contours for these same seven acoustic measures as functions of angle and distance from the source.
- Publication:
-
USAF bioenvironmental noise data handbook. Volume 163: GPC-28 compressor
- Pub Date:
- May 1982
- Bibcode:
- 1982bend..163.....R
- Keywords:
-
- Bioacoustics;
- Compressors;
- Internal Combustion Engines;
- Noise (Sound);
- Noise Pollution;
- Airborne Equipment;
- Aircraft Maintenance;
- Ear Protectors;
- Exposure;
- Ground Crews;
- Handbooks;
- Noise Intensity;
- Noise Measurement;
- Psychoacoustics;
- Sound Pressure;
- Speech;
- Tables (Data);
- Acoustics