Flow visualization in a cryogenic wind tunnel using holography
Abstract
Results of holographic flow visualization from tests made in the Langley 0.3 meter transonic cryogenic tunnel are presented. The tunnel was operated over a temperature range from 100 to 300 K and a pressure range from 1.1 to 4 atm. Interferometry at the facility may be of limited use at the low temperature high pressure conditions because of the jumbled nature of the reference fringes. The shadowgraph technique appears to be the best means of visualizing shocks at these high density conditions. The spot size at the focus of the reconstructed beams was measured and used as an indicator of density fluctuations in the flow field. These density fluctuations appear to be caused by temperature fluctuations of the test gas which are relatively independent of tunnel conditions.
- Publication:
-
NASA STI/Recon Technical Report N
- Pub Date:
- November 1982
- Bibcode:
- 1982STIN...8312395B
- Keywords:
-
- Cryogenic Wind Tunnels;
- Flow Visualization;
- Holography;
- Transonic Wind Tunnels;
- Density (Mass/Volume);
- Flow Distribution;
- Holographic Interferometry;
- Pressure Effects;
- Shadowgraph Photography;
- Temperature Effects;
- Instrumentation and Photography