An investigation of assembly and performance of a Resistoflex dynatube 1/4 inch fitting
Abstract
Installation of titanium (6Al-4V) threaded fittings on 1/4 in. tubing is sensitive to workmanship and to the state of repair of the installation tooling. Tooling with very slight out-of-specification imperfections produces less than optimum swaged fittings. A significant quantity of samples were fabricated and X-rays were used to determine the depth of swage. Joint performance was assessed through static and dynamic testing.