Temperature distributions in a megabit bubble chip
Abstract
For a large-capacity large-size bubble chip, various operating parameter nonuniformities across the chip as well as garnet material and device processing inhomogeneities could be a source of considerable bias margin loss. An example is chip temperature nonuniformity due to detector heating. In an attempt to estimate the chip margin loss due to local temperature nonuniformities, temperature distributions in a Mbit chip have been mapped as a function of detector current amplitude. Temperatures at several regions in the chip were monitored by measuring the resistance of active device components, such as transfer-in gate and replicate/transfer-out gate conductors, and detectors themselves that are of full-shorted 200-element chevron stretcher type. A simple physical model has been developed which, together with various measured local temperatures, provides complete two-dimensional mapping of temperature distributions in the chip.
- Publication:
-
IEEE Transactions on Magnetics
- Pub Date:
- March 1979
- DOI:
- Bibcode:
- 1979ITM....15..921K
- Keywords:
-
- Bits;
- Bubble Memory Devices;
- Chips (Memory Devices);
- Temperature Distribution;
- Electronic Equipment Tests;
- Garnets;
- Gates (Circuits);
- Mathematical Models;
- Electronics and Electrical Engineering