Exploratory study of temperatures produced by self-heating of residential branch circuit wiring when surrounded by thermal insulation
Abstract
Preliminary determination under laboratory conditions of temperatures that might develop on residential electrical wiring covered by thermal insulation when carrying rated currents or currents slightly above rated values is reported. The results show that temperatures on conductors surrounded by thermal insulation can greatly exceed the maximum service temperatures for the wire insulation. Results also show that some types of insulation currently used to retrofit buildings may fill wall outlet boxes and contact the current carrying elements and connections of duplex receptacles.
- Publication:
-
Final Report National Bureau of Standards
- Pub Date:
- July 1978
- Bibcode:
- 1978nbs..reptT....B
- Keywords:
-
- Electrical Insulation;
- Thermal Insulation;
- Wiring;
- Electric Conductors;
- Temperature;
- Electronics and Electrical Engineering