Effects of film injection angle on turbine vane cooling
Abstract
Film ejection from discrete holes in the suction surface of a turbine vane was studied for hole axes (1) slanted 30 deg to the surface in the streamwise direction and (2) slanted 30 deg to the surface and 45 deg from the streamwise direction toward the hub. The holes were near the throat area in a five-row staggered array with 8-diameter spacing. Mass flux ratios were as high as 1.2. The data were obtained in an annular sector cascade at conditions where both the ratio of the boundary layer momentum thickness-to-hole diameter and the momentum thickness Reynolds number were typical of an advanced turbofan engine at both takeoff and cruise. Wall temperatures were measured downstream of each of the rows of holes. Results of this study are expressed as a comparison of cooling effectiveness between the in-line angle injection and the compound-angle injection as a function of mass flux ratio. These heat transfer results are also compared with the results of a referenced flow visualization study. Also included is a closed-form analytical solution for temperature within the film cooled wall.
- Publication:
-
NASA STI/Recon Technical Report N
- Pub Date:
- December 1977
- Bibcode:
- 1977STIN...7813379G
- Keywords:
-
- Film Cooling;
- Heat Transfer;
- Turbine Blades;
- Cooling Systems;
- Liquid Cooling;
- Liquid Injection;
- Fluid Mechanics and Heat Transfer