Product improvement program coaxial magnetron for AN/MPQ-4A radar set
Abstract
Magnetrons were designed and manufactured to the same parameters described in the original proposal submitted in April 1973. Ten of these tubes were passed through acceptance tests and delivered to ECOM. The remaining five tubes were run through qualification tests and two of these five tubes were run on life test for 1,000 hours each before submission to ECOM. Performance data is given for all tubes and qualification data for the five tubes. An analysis of tube failures during the program is included.
- Publication:
-
NASA STI/Recon Technical Report N
- Pub Date:
- September 1975
- Bibcode:
- 1975STIN...7630476B
- Keywords:
-
- Magnetrons;
- Performance Tests;
- Radar;
- Failure Analysis;
- Microwave Tubes;
- Tables (Data);
- Electronics and Electrical Engineering