High-resolution width-modulated pulse rebalance electronics for strapdown gyroscopes and accelerometers
Abstract
Three different rebalance electronic loops were designed, implemented, and evaluated. The loops were width-modulated binary types using a 614.4 kHz keying signal; they were developed to accommodate the following three inertial sensors with the indicated resolution values: (1) Kearfott 2412 accelerometer - resolution = 260 micro-g/data pulse, (2) Honeywell GG334 gyroscope - resolution = 3.9 milli-arc-sec/data pulse, (3) Kearfott 2401-009 accelerometer - resolution = 144 milli-g/data pulse. Design theory, details of the design implementation, and experimental results for each loop are presented.
- Publication:
-
NASA STI/Recon Technical Report N
- Pub Date:
- September 1974
- Bibcode:
- 1974STIN...7613375K
- Keywords:
-
- Accelerometers;
- Gyroscopes;
- Pulse Duration Modulation;
- Strapdown Inertial Guidance;
- Design Analysis;
- Loops;
- Random Noise;
- Signal Processing;
- Transfer Functions;
- Electronics and Electrical Engineering