Comparison of calculated results from 2 analytical models with measured data from a heat-exchanger flow test
Abstract
Predicted results from both a network flow model and a turbulent flow model were compared with measured results from an air flow test on a half-scale model of the auxiliary heat exchanger for a high temperature gas cooled reactor. Measurements of both velocity and pressure were made within the heat exchanger shell side flow field. These measurements were compared with calculated results from both a network flow model and a turbulent flow model. Both analytical models predicted early identical results which, except for some minor anomalies, compared favorably with the measured data.