Reflector surface measurements of the IRAM 30-m radio telescope
Abstract
Surface measurements of the IRAM 30 m radio reflector made with a theodolite-laser-tape system are described. The results obtained with this survey system agree with holography measurements made at 22 GHz (Morris 1985).
- Publication:
-
International Journal of Infrared and Millimeter Waves
- Pub Date:
- January 1986
- DOI:
- 10.1007/BF01011066
- Bibcode:
- 1986IJIMW...7..121G
- Keywords:
-
- Radio Telescopes;
- Reflectors;
- Surface Properties;
- Theodolites;
- Accuracy;
- Atmospheric Turbulence;
- Data Reduction;
- Diodes;
- Holography;
- Electronics and Electrical Engineering